RVS-DN
Mains Voltage
Control Supply Voltage (Terminals 1 and 3)
Control Input Voltage (Terminals 4 to 9)
Options
Front Panel
Notes
(1) RVS-DN 950-3000A, RVS-DN 1000V and RVS-DN 1200V must be operated with a bypass contactor. For usage without bypass contactor consult the factory.
(2) Preparation for bypass contactor is standard in RVS-DN 85-170A
(3) Only one option, either 3M or 3P or 3D may be installed in one RVS-DN
(4) Only one option, either 4 or 5 or 7 or T may be installed in one SRVS-DN
(5) All options must be factory installed in RVS-DN 8-72A
(6) Current transformers (CTs) for SI-DN950A and up are designed to allow installation within 1.5m from the RVS-DN
(use the CTs for the RVS-DN only!)
(7) For more than one option indicate, for example: 8-9 for Harsh environment and preparation for bypass contactor. Ordering Example: RVS-DN rated 820A, mains voltage -230V, Control Supply voltage -115V, Control Input -115V, Modbus communication card, Analog card, Harsh environment treatment, preparation for bypass and standard front panel: RVS-DN 820 - 400 - 115 - 115 - 3M - 5 - 8 - 9 – S (note that 400V mains is for 230-400V)
RVS-DX
Mains Voltage
Control Voltage
Notes: Control voltage can be changed on site for RVS-DX up to 170A.
Options
Notes
Front Panel
Example
RVS-DX rated 170A, mains voltage- 230V, control voltage- 115V, Modbus communication card, Analog card, Harsh environment treatment and standard front panel:
RVS-DX170-400-115-3M-5-8-S
(note that 400V mains is for 230-400V)
RVS-DXM
Mains Voltage
Control Voltage
Note: Control voltage cannot be modified on site.
Options
Notes
Front Panel
Example
RVS-DXM rated 840A, mains voltage- 230V, control voltage- 115V, Modbus communication card, Analog card, Harsh environment treatment, option 66 bus bars arrangement and standard front panel:
RVS-DXM 840 - 400 - 115 - 3M - 5 - 8 - 66 - S
iStart
Mains Voltage
Control Voltage (Terminal A1, A2)
Note: Control voltage cannot be modified on site.
Control Input Voltage (Terminals 1-5)
Note: Control voltage cannot be modified on site.
Options
Notes
(1) Only one Communication option from 3M, 3P, 3D.
(2) Only one option from: 4, 5, 6.
(3) You can install these options on site.
(4) You can install these options on site for 17A to 170A only. For 230A and up units supplied with fan as standard.
(5) Factory installed option.
(6) Only for 17A to 170A only.
(7) Only for 230A to 430A only.
(8) One option can be installed – either 33 or 66 or 36 or 63. Only available for 230A and above.
Front Panel
RVS-AX
Full Load Current
Mains Voltage
Options
Solbrake
Mains Voltage
Options
Front Panel
SI-HCS (TPS)
Notes: (1) Consult factory
Mains Voltage
Control Voltage
Notes: (1) For DC control voltage or control inputs voltage - consult factory.
Control Inputs Voltage
Notes: (1) For DC control voltage or control inputs voltage - consult factory.
Options
Notes
Front Panel
MPS 3000
Construction
Thermal Sensor
Supply/Control Voltage
Required Options
Note: (Option “P” available only in vertical construction. For option “P” in horizontal construction – Consult factory)
Front Panel
Additional Request
Note: Only requires when front Modbus Comm. Port is needed - for example when Profibus is installed in the rear side.
TPR-6
Temperature
Control Voltage
Communication
Options
Front Panel
MIP-6
Mains Voltage
Notes
(1) MIP MV1 is supplied with a resistor unit RU-7.
(2) MIP MV2 is supplied with a resistor unit RU-13.
Options
Front Panel
HRVS-DN
Please contact us for a quote
MV-TPS
DriveStart
Please contact us for a quote
MPS-6
C/T Secondary
Control Voltage
Thermal Sensor
Options