Description
DX Brochure Instruction ManualThe RVS-DX and RVS-DXM incorporate enhanced soft-start/stop characteristics and motor protection features with a built-in bypass in a compact design, suitable for nearly any application.
Advanced Features
- Superior soft starting & soft stopping
- Comprehensive motor protection
- RS 485 Modbus communications
- Frequency auto-tracking 45-65Hz
- User friendly
- Line or inside delta connection
- Current limit
- Unique pump control software
- Torque and current control
- Dual-adjustment
- Slow speed with reversing
- Pulse start
Digital Controller
- LCD – 2 lines x 16 characters
- Selectable languages: English, German, French & Spanish
- Four LEDs: On, Run, Ramp Up/Down & Fault
- Statistical data
- Full description parameter settings
Protection Features
- Too many starts
- Long start time (Stall)
- Shear-pin (Start+ Run + Jam)
- Electronic overload
- Under current
- Phase loss & sequence
- Under, over, no voltage
- Load loss
- Shorted SCR
- Starter over-temperature
- External fault
Models 8 – 170A, 230V-600V

How To Order
Example:
RVS-DX – 145V – 480V – 115V – 115V – 3M
145V
Rated Current
480V
Mains Voltage
400V = 230-400VAC, +10%/-15%, 50/60Hz.
480V = 480VAC, +10%/-15%, 50/60Hz.
600V = 600VAC, +10%/-15%, 50/60Hz.
400V = 230-400VAC, +10%/-15%, 50/60Hz.
480V = 480VAC, +10%/-15%, 50/60Hz.
600V = 600VAC, +10%/-15%, 50/60Hz.
115V
Control Voltage
115 VAC
230 VAC
115 VAC
230 VAC
115V
Control Input Voltage
3M
Options
0 = No Options
3M = Communication RS-485 (MODBUS)
3P = Communication Profibus
3D = Communication RS-485 (MODBUS) and external DeviceNet to Modbus Gateway
5 = Analog Card – Thermistor in and Analog out
8 = Harsh environment treatment
D = Remote panel mounting, replacing the original panel. (supplied with 1.5 m cable)
U = UL & cUL approval
H = Special character set LCD display
0 = No Options
3M = Communication RS-485 (MODBUS)
3P = Communication Profibus
3D = Communication RS-485 (MODBUS) and external DeviceNet to Modbus Gateway
5 = Analog Card – Thermistor in and Analog out
8 = Harsh environment treatment
D = Remote panel mounting, replacing the original panel. (supplied with 1.5 m cable)
U = UL & cUL approval
H = Special character set LCD display

Advanced Features
- Ambient operating temp 14 to +/-122F
- Comprehensive motor protection
- Frequency auto-tracking 45-65Hz
- User friendly
- Line or inside delta connection
- Current limit
- Unique pump control software
- Torque and current control
- Dual-adjustment
- Slow speed with reversing
- Pulse start
Protection Features
- Comprehensive, built-in motor protection (same as RVS-DX)
- Multi-language, 2-line x 16 character display
- Four LEDs (On, Run, Ramp Up/Down 7 Fault)
- Statistical Data
- Full description parameter settings
- Remote keypad option
Flexibility by Design
- Line & load connections
- Choose from six bus bars (top & bottom) for flexible installation
- Rated: 350% for 30 seconds; std. 65AIC (breaker), 100kAIC (fuses)
Models 210 – 1100A, 230-690V

*See RVS-DX for lower-rated models.
How To Order
Example:
RVS-DXM – 310A – 690V – 115V – 115V – 3M
310A
Rated Current
690V
Mains Voltage
400V = 208-400VAC, +10%/-15%, 50/60Hz.
600V = 440-600VAC, +10%/-15%, 50/60Hz.
690V = 600-690VAC, +10%/-15%, 50/60Hz.
400V = 208-400VAC, +10%/-15%, 50/60Hz.
600V = 440-600VAC, +10%/-15%, 50/60Hz.
690V = 600-690VAC, +10%/-15%, 50/60Hz.
115V
Control Voltage
115 VAC
230 VAC
115 VAC
230 VAC
115V
Control Input Voltage
3M
Options
0 = No Options
3M = Communication RS-485 (MODBUS)
3P = Communication Profibus
3D = Communication RS-485 (MODBUS) and external DeviceNet to Modbus Gateway
5 = Analog Card – Thermistor in and Analog out
8 = Harsh environment treatment
D = Remote panel mounting, replacing the original panel. (supplied with 1.5 m cable)
33 = 3 Inputs and 3 Outputs Bus bars
66 = 6 Input/Output Bus bars on Bottom side and 6 Input/Output Bus bars on Top side
36 = 3 Input Bus bars on Top side and 6 Input/Output bars on Bottom side
63 = 6 Input/Output Bus bars on Top and 3 output Bus bars on Bottom
U = UL & cUL approval
H = Special character set LCD display
0 = No Options
3M = Communication RS-485 (MODBUS)
3P = Communication Profibus
3D = Communication RS-485 (MODBUS) and external DeviceNet to Modbus Gateway
5 = Analog Card – Thermistor in and Analog out
8 = Harsh environment treatment
D = Remote panel mounting, replacing the original panel. (supplied with 1.5 m cable)
33 = 3 Inputs and 3 Outputs Bus bars
66 = 6 Input/Output Bus bars on Bottom side and 6 Input/Output Bus bars on Top side
36 = 3 Input Bus bars on Top side and 6 Input/Output bars on Bottom side
63 = 6 Input/Output Bus bars on Top and 3 output Bus bars on Bottom
U = UL & cUL approval
H = Special character set LCD display