RVS-DX and RVS-DXM Standard Duty Soft Starters with built-in bypass

Category:

Description

DX Brochure
Instruction Manual

The RVS-DX and RVS-DXM incorporate enhanced soft-start/stop characteristics and motor protection features with a built-in bypass in a compact design, suitable for nearly any application.

Advanced Features

  • Superior soft starting & soft stopping
  • Comprehensive motor protection
  • RS 485 Modbus communications
  • Frequency auto-tracking 45-65Hz
  • User friendly
  • Line or inside delta connection
  • Current limit
  • Unique pump control software
  • Torque and current control
  • Dual-adjustment
  • Slow speed with reversing
  • Pulse start

Digital Controller

  • LCD – 2 lines x 16 characters
  • Selectable languages: English, German, French & Spanish
  • Four LEDs: On, Run, Ramp Up/Down & Fault
  • Statistical data
  • Full description parameter settings

Protection Features

  • Too many starts
  • Long start time (Stall)
  • Shear-pin (Start+ Run + Jam)
  • Electronic overload
  • Under current
  • Phase loss & sequence
  • Under, over, no voltage
  • Load loss
  • Shorted SCR
  • Starter over-temperature
  • External fault

Models 8 – 170A, 230V-600V

How To Order

Example:

RVS-DX   –   145V   –   480V   –   115V   –   115V   –   3M

145V
Rated Current

 

480V
Mains Voltage
400V = 230-400VAC, +10%/-15%, 50/60Hz.
480V = 480VAC, +10%/-15%, 50/60Hz.
600V = 600VAC, +10%/-15%, 50/60Hz.
115V
Control Voltage
115 VAC
230 VAC
115V
Control Input Voltage
3M
Options
0 = No Options
3M = Communication RS-485 (MODBUS) 
3P = Communication Profibus 
3D = Communication RS-485 (MODBUS) and external DeviceNet to Modbus Gateway
5 = Analog Card – Thermistor in and Analog out 

8 = Harsh environment treatment
D = Remote panel mounting, replacing the original panel. (supplied with 1.5 m cable) 
U = UL & cUL approval
H = Special character set LCD display

DXM Brochure
Instruction Manual

Advanced Features

  • Ambient operating temp 14 to +/-122F
  • Comprehensive motor protection
  • Frequency auto-tracking 45-65Hz
  • User friendly
  • Line or inside delta connection
  • Current limit
  • Unique pump control software
  • Torque and current control
  • Dual-adjustment
  • Slow speed with reversing
  • Pulse start

Protection Features

  • Comprehensive, built-in motor protection (same as RVS-DX)
  • Multi-language, 2-line x 16 character display
  • Four LEDs (On, Run, Ramp Up/Down 7 Fault)
  • Statistical Data
  • Full description parameter settings
  • Remote keypad option

Flexibility by Design

  • Line & load connections
  • Choose from six bus bars (top & bottom) for flexible installation
  • Rated: 350% for 30 seconds; std. 65AIC (breaker), 100kAIC (fuses)

Models 210 – 1100A, 230-690V

*See RVS-DX for lower-rated models.

How To Order

Example:

RVS-DXM   –   310A   –   690V   –   115V   –   115V   –   3M

310A
Rated Current
690V
Mains Voltage
400V = 208-400VAC, +10%/-15%, 50/60Hz.
600V = 440-600VAC, +10%/-15%, 50/60Hz.
690V = 600-690VAC, +10%/-15%, 50/60Hz.
115V
Control Voltage
115 VAC
230 VAC
115V
Control Input Voltage
3M
Options
0 = No Options
3M = Communication RS-485 (MODBUS) 
3P = Communication Profibus
3D = Communication RS-485 (MODBUS) and external DeviceNet to Modbus Gateway 

5 = Analog Card – Thermistor in and Analog out 
8 = Harsh environment treatment
D = Remote panel mounting, replacing the original panel. (supplied with 1.5 m cable)
33 = 3 Inputs and 3 Outputs Bus bars
66 = 6 Input/Output Bus bars on Bottom side and 6 Input/Output Bus bars on Top side
36 = 3 Input Bus bars on Top side and 6 Input/Output bars on Bottom side
63 = 6 Input/Output Bus bars on Top and 3 output Bus bars on Bottom
U = UL & cUL approval
H = Special character set LCD display